Email liên hệ:

info@systech.vn

Hỗ trợ dịch vụ:

+84(0) 83 383 1313

ULTRAVOLT HIGH VOLTAGE SUPPLY

ULTRAVOLT HIGH VOLTAGE SUPPLY
ULTRAVOLT HIGH VOLTAGE SUPPLY

The A Series consists of miniature, PCB-mount, high voltage, regulated DC-DC converters. Designed and built utilizing state-of-the-art power-conversion topology, these units feature surface-mount technology and encapsulation techniques that provide high reliability and performance.
Model: ULTRAVOLT A SERIES
Nhà sản xuất: Advancedenergy

PRODUCT HIGHLIGHTS
Eight models from 0 to 62 V through 0 to 6 kV
4, 20, or 30 W of output power
Maximum Iout capability down to 0 V
Wide input voltage range
Available with Ripple Stripper® filter (-F option)
Indefinite output short-circuit protection
Output current monitor
Fixed-frequency, low-stored-energy design
> 430,000 hour MTBF at 65°C (149°F)
UL/cUL recognized component; CE Mark (LVD and RoHS)
TYPICAL APPLICATIONS
Bias supplies
Electrostatic detectors
Mass spectrometers
Photomultiplier tubes (PMTs)  

Parameter Conditions Models Units
Input 12 V
Voltage
Range
Full Power +11 to 16 VDC
Voltage
Range
Derated Power
Range
+9 to 32 VDC
Current Standby / Disable < 30 mA
Current No Load, Max Eout < 100 mA
Current Max Load, Max
Eout
~ 400 mA
AC Ripple
Current
Nominal Input,
Full Load
< 80 mA p-p
Output 1/16A 1/8A 1/4A 1/2A
Voltage
Range
Nominal Input 0 to 62 0 to 125 0 to 250 0 to 500 VDC
Nominal Input Voltage 12 24 24 12 24 24 12 24 24 12 24 24 VDC
Power Nominal Input, Max
Eout
4 20 30 4 20 30 4 20 30 4 20 30 W
Current Iout Entire Output
Voltage Range
64 320 480 32 160 240 16 80 120 8 40 60 mA
Current
Monitor
Scaling
Full Load 0.985 3.90 7.40 438.4 1860.5 2891.5 0.985 3.90 7.40 438.4 1860.5 2891.5 mA/V
Voltage
Monitor
Scaling
With -Y5 option 10:1 ± 2% into 10 MΩ 10:1 ± 2% into 10 MΩ -
Ripple Full Load, Max
Eout
0.02 0.03 0.05 0.013 0.015 0.016 0.01 0.04 0.048 0.001 0.02 0.017 %V p-p
Ripple
with -F-M
Option*
Full Load, Max
Eout, 300 pF
Bypass Cap
0.002 0.004 0.006 0.0048 0.0056 0.006 0.0052 0.0028 0.005 0.001 0.0138 0.0016 %V p-p
Dynamic
Load
Regulation
½ to Full Load,
Max Eout per 0.1
mA
< 0.12 < 0.12 < 0.12 < 0.12 < 0.12 < 0.12 < 0.20 < 0.20 < 0.20 < 0.50 < 0.50 < 0.50 V pk
Line
Regulation
Nom. Input, Max
Eout, Full Power
< 0.01 % < 0.01 % VDC
Static Load
Regulation
No Load to Full
Load, Max Eout
< 0.01% < 0.01% VDC
Stability 30 Min. warmup,
per 8 hr/ Per Day
< 0.01%/< 0.02% < 0.01%/< 0.02% VDC
Programming & Controls All Types
Input
Impedance
Nominal Input + output models 1.1 MΩ to GND, - output models 1.1 MΩ to +5 Vref
Adjust
Resistance
Typical
Potentiometer
Values
10 to 100 K (Pot. across Vref. and signal GND, wiper to adjust) Ω
Adjust
Logic
0 to +5 for +Out, +5
to 0 for - Out
+4.64 VDC for +output or +0.36 for -output = nominal Eout -
Output
Voltage &
Impedance
T=+25°C + 5.00 VDC ± 2%, Zout = 464 Ω ± 1% -
Enable/Disable 0 to +0.5 disable, +2.4 to 32 enable (default = enable) VDC




0833831313